The measurement of lung water
Introduction:
In this review, we compare the spectrum of currently available methods for quantifying pulmonary edema in patients.
Review:
Imaging and indicator dilution techniques comprise the most common strategies for measuring lung water at the bedside. The most accurate (within 10% of the gravimetric gold standard) and most reproducible (< 5% between-test variation) are also, unfortunately, the most expensive and most difficult to implement for purposes of large-scale clinical trials or for routine clinical practice.
Conclusion:
The standard chest radiograph remains the best screening test for the detection of pulmonary edema. Indicator-dilution techniques are probably the best available method at present for quantitation in patient groups.
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[ "009:25" ] |
| contactPoint |
{ "fn": "NIH", "@type": "vcard:Contact", "hasEmail": "mailto:info@nih.gov" } |
| description | Introduction: In this review, we compare the spectrum of currently available methods for quantifying pulmonary edema in patients. Review: Imaging and indicator dilution techniques comprise the most common strategies for measuring lung water at the bedside. The most accurate (within 10% of the gravimetric gold standard) and most reproducible (< 5% between-test variation) are also, unfortunately, the most expensive and most difficult to implement for purposes of large-scale clinical trials or for routine clinical practice. Conclusion: The standard chest radiograph remains the best screening test for the detection of pulmonary edema. Indicator-dilution techniques are probably the best available method at present for quantitation in patient groups. |
| distribution |
[ { "@type": "dcat:Distribution", "title": "Official Government Data Source", "mediaType": "text/html", "description": "Visit the original government dataset for complete information, documentation, and data access.", "downloadURL": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC137228/" } ] |
| identifier | https://healthdata.gov/api/views/nusx-fpru |
| issued | 2025-07-14 |
| keyword |
[ "imaging-techniques", "indicator-dilution", "lung-water", "nih", "pulmonary-edema" ] |
| landingPage | https://healthdata.gov/d/nusx-fpru |
| modified | 2025-09-06 |
| programCode |
[ "009:032" ] |
| publisher |
{ "name": "National Institutes of Health", "@type": "org:Organization" } |
| theme |
[ "NIH" ] |
| title | The measurement of lung water |