Practising evidence-based medicine: the design and implementation of a multidisciplinary team-driven extubation protocol

Metadata Updated: September 6, 2025

Background Evidence from recent literature shows that protocol-directed extubation is a useful approach to liberate patients from mechanical ventilation (MV). However, research evidence does not necessarily provide guidance on how to implement changes in individual intensive care units (ICUs). We conducted the present study to determine whether such an evidence-based strategy can be implemented safely and effectively using a multidisciplinary team (MDT) approach.

      Method
      We designed a MDT-driven extubation protocol. Multiple meetings were held to encourage constructive criticism of the design by attending physicians, nurses and respiratory care practitioners (RCPs), in order to define a protocol that was evidence based and acceptable to all clinical staff involved in the process of extubation. It was subsequently implemented and evaluated in our medical/ surgical ICU. Outcomes included response of the MDT to the initiative, duration of MV and stay in the ICU, as well as reintubation rate.


      Results
      The MDT responded favourably to the design and implementation of this MDT-driven extubation protocol, because it provided greater autonomy to the staff. Outcomes reported in the literature and in the historical control group were compared with those in the protocol group, and indicated similar durations of MV and ICU stay, as well as reintubation rates. No adverse events were documented.


      Conclusion
      An MDT approach to protocol-directed extubation can be implemented safely and effectively in a multidisciplinary ICU. Such an effort is viewed favourably by the entire team and is useful in enhancing team building.

Access & Use Information

Public: This dataset is intended for public access and use. License: No license information was provided. If this work was prepared by an officer or employee of the United States government as part of that person's official duties it is considered a U.S. Government Work.

Downloads & Resources

Dates

Metadata Created Date July 24, 2025
Metadata Updated Date September 6, 2025

Metadata Source

Harvested from Healthdata.gov

Additional Metadata

Resource Type Dataset
Metadata Created Date July 24, 2025
Metadata Updated Date September 6, 2025
Publisher National Institutes of Health
Maintainer
NIH
Identifier https://healthdata.gov/api/views/6maa-wwbe
Data First Published 2025-07-14
Data Last Modified 2025-09-06
Category NIH
Public Access Level public
Bureau Code 009:25
Metadata Context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
Metadata Catalog ID https://healthdata.gov/data.json
Schema Version https://project-open-data.cio.gov/v1.1/schema
Catalog Describedby https://project-open-data.cio.gov/v1.1/schema/catalog.json
Harvest Object Id 5b83d728-42d9-4940-8b1e-b6f7b18388d0
Harvest Source Id 651e43b2-321c-4e4c-b86a-835cfc342cb0
Harvest Source Title Healthdata.gov
Homepage URL https://healthdata.gov/d/6maa-wwbe
Program Code 009:048
Source Datajson Identifier True
Source Hash f3b9f40a1fddb77960ffc93c3ad13905d3df2cad9ead94e98f5c523e1862298f
Source Schema Version 1.1

Didn't find what you're looking for? Suggest a dataset here.