S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement
Resources
2 resources available
-
RISE Item Details Page URL for "S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement"
TEXT/HTML -
PDF File for "S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement"
APPLICATION/PDF
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| accrualPeriodicity | irregular |
| bureauCode |
[ "010:10" ] |
| contactPoint |
{ "fn": "RISE Team", "@type": "vcard:Contact", "hasEmail": "mailto:data@usbr.gov" } |
| description | The Winter-Kennedy (WK) method of flow measurement correlates a difference in pressure at a cross-section of the scroll case to the discharge through the hydropower unit. Many of Reclamation’s hydropower units include pressure taps configured for WK measurements but few have been used. Utilizing an existing flow measurement system with their original calibration could provide a significant cost savings for flow measurement equipment and provide value for monitoring water quantities or even unit efficiency. Limitations of this method include changes to the condition of the interior pressure taps, penstock surface roughness, coating degradation, and many other factors that influence the calibration. The intent of this study was to determine the value of existing WK systems by comparing flow estimates from original WK calibrations to an absolute flow rate reference. Field tests were done on six different WK pressure tap systems at three Reclamation hydropower plants. Equipment and original calibrations were at least 40 years old for each unit tested. Test results showed that the original calibrations have drifted significantly and that for each case new calibration tests would be required for the flow predictions to be used. |
| distribution |
[ { "@type": "dcat:Distribution", "title": "RISE Item Details Page URL for "S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement"", "accessURL": "https://data.usbr.gov/catalog/8011/item/128613", "mediaType": "text/html", "description": "Landing page for "S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement"" }, { "@type": "dcat:Distribution", "title": "PDF File for "S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement"", "mediaType": "application/pdf", "description": ""S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement" as a PDF file", "downloadURL": "https://data.usbr.gov/rise/content-rise-public/rise/catalog-item/binary/S&T%20Final%20Report%2020048%20Winter-Kennedy_FINAL%20508.pdf" } ] |
| identifier | https://datainventory.usbr.gov/rise/item/128613 |
| keyword |
[ "Flow Measurement", "Hydropower", "Testing", "Winter-Kennedy Method" ] |
| landingPage | https://data.usbr.gov/catalog/8011/item/128613 |
| modified | 2026-06-04T17:10:30Z |
| publisher |
{ "name": "Bureau of Reclamation", "@type": "org:Organization" } |
| spatial |
"{"type":"Polygon","coordinates":[[[-105.12484,39.72238],[-105.1217,39.72366],[-105.1199,39.72123],[-105.12164,39.72052],[-105.12285,39.72213],[-105.12431,39.72153],[-105.12484,39.72238]]]}"
|
| title | S&T Project 20048 Final Report: Utilizing the Winter-Kennedy Method for Hydropower Flow Measurement |