Sodar - NREL Scintec MFAS Wind Profiler, Decker Ranch Airstrip - Raw Data

Metadata Updated: April 26, 2022

Overview

The dataset includes 15-minute average wind speed and direction records from 30 m to 330 m above ground level (AGL) in 10-m range gates. Data were collected by a Scintec MFAS wind profiler installed at the Decker Ranch in Oregon, about 4.4 km southeast of Kent, Ore., and are intended for validating WFIP2 model improvements.

Data Details

Instrument location: * N 45°09'54.42" (N 45.165117)
* W120°39'20.87" (W 120.655799)

Instrument clock and computer system time set to UTC.

Data Quality

The Scintec MFAS wind profiler instrument installed at the Decker Ranch is capable of measuring at heights up to 1000 m. For this study, the maximum height was set to 330 m. The instrument was oriented to true north, so no corrections to the wind direction should be made. Scintec wind profilers come with the APRun software package, which performs data collection and quality control (QC), among other functions. Version 1.46 of APRun was used in this study.

The APRun manual states: The primary results are checked against local signal quality criteria, combined signal quality criteria and two-dimensional spatial/temporal consistency tests. Any data that does not pass all quality control tests is devalidated and removed.

Devalidation means replacing the value with an error value, usually a series of ‘9’s, such as 99.99 or 999.99. Not all devalidated data are actually removed from the .mnd files, so the user must filter them out. There are some error flags that indicate the type of error, but these are not included in the .mnd files, and we have no access to them.

Because QC already has been performed by APRun, our QC procedures consisted of removing samples with error values and performing a visual inspection of the data to see if larger patterns indicated any kind of problem.

There are 623 gaps of two hours or less and 61 gaps of more than two hours. The longest gap is 15.31 days, from 2016-12-07 03:00Z to 2016-12-22 10:30Z. All gaps that exceed two hours are listed in file: Decker_Ranch_gaps.txt.

Access & Use Information

Public: This dataset is intended for public access and use. License: Creative Commons Attribution

Downloads & Resources

Dates

Metadata Created Date August 4, 2021
Metadata Updated Date April 26, 2022

Metadata Source

Harvested from OpenEI data.json

Additional Metadata

Resource Type Dataset
Metadata Created Date August 4, 2021
Metadata Updated Date April 26, 2022
Publisher Wind Energy Technologies Office (WETO)
Maintainer
Doi 10.21947/1328901
Identifier https://data.openei.org/submissions/4335
Data First Published 2015-10-28T00:00:00Z
Data Last Modified 2021-10-11T00:00:00Z
Public Access Level public
Bureau Code 019:20
Metadata Context https://openei.org/data.json
Metadata Catalog ID https://openei.org/data.json
Schema Version https://project-open-data.cio.gov/v1.1/schema
Catalog Describedby https://project-open-data.cio.gov/v1.1/schema/catalog.json
Data Quality True
Harvest Object Id 32d3ae64-ff17-4823-bb25-c18a99edc36c
Harvest Source Id 7cbf9085-0290-4e9f-bec1-91653baeddfd
Harvest Source Title OpenEI data.json
Homepage URL https://a2e.energy.gov/data/wfip2/sodar.z10.00
License https://creativecommons.org/licenses/by/4.0/
Program Code 019:010
Projectnumber 67025
Projecttitle Wind Data Hub
Source Datajson Identifier True
Source Hash 49caa3bab40e8027605afafe0f02c7dde5c76cec
Source Schema Version 1.1

Didn't find what you're looking for? Suggest a dataset here.