S-parameters of Parylene C microwave microfluidic devices

Metadata Updated: January 7, 2023

Broadband S-parameter measurements of Parylene C microwave microfluidic devices from 100 MHz - 110 GHz. The Parylene C devices consisted of 400 nm platinum coplanar waveguides (CPW) (50 um center conductor, 5 um gaps, 200 um ground planes) deposited on fused silica with 6.5 um of Parylene C on top, capped with a PDMS microfluidic layer aligned over the CPWs. The dimensions of the PDMS microfluidic channels were approximately 210 um wide by 100 um deep. The total CPW line length was 10.000 mm and the channel length was 4.160 mm, where the channel was aligned over the center of the CPW. We measured the S-parameters of Parylene C devices filled with three different fluid conditions at different intervals over a 2 month period: H2O at 20 degrees Celsius, 1xPBS (phosphate-buffered saline) at 20 degrees Celsius, and 1xPBS at 37 degrees Celsius. We obtained measurements of both the fluid-filled and empty channel at each measurement day. We measured broadband S-parameters with a vector network analyzer and extender heads at a source power of -17 dBm on a temperature-controlled probe station. The S-parameters were calibrated to the probe tips with measurements of a gold reference chip in combination with multiline TRL in the NIST Microwave Uncertainty Framework. The differences in S-parameters from day 0 were plotted over time to observe changes in the dielectric properties of the Parylene C device during soaking.

Access & Use Information

Public: This dataset is intended for public access and use. License: See this page for license information.

Downloads & Resources

Dates

Metadata Created Date January 7, 2023
Metadata Updated Date January 7, 2023
Data Update Frequency irregular

Metadata Source

Harvested from NIST

Additional Metadata

Resource Type Dataset
Metadata Created Date January 7, 2023
Metadata Updated Date January 7, 2023
Publisher National Institute of Standards and Technology
Maintainer
Identifier ark:/88434/mds2-2808
Data First Published 2023-01-04
Language en
Data Last Modified 2022-10-03 00:00:00
Category Bioscience:Biomaterials, Electronics:Electromagnetics, Materials:Polymers, Metrology:Electrical/electromagnetic metrology, Physics:Spectroscopy
Public Access Level public
Data Update Frequency irregular
Bureau Code 006:55
Metadata Context https://project-open-data.cio.gov/v1.1/schema/data.json
Schema Version https://project-open-data.cio.gov/v1.1/schema
Catalog Describedby https://project-open-data.cio.gov/v1.1/schema/catalog.json
Harvest Object Id f4184acb-fe91-44ed-9435-ebc031d9f349
Harvest Source Id 74e175d9-66b3-4323-ac98-e2a90eeb93c0
Harvest Source Title NIST
Homepage URL https://data.nist.gov/od/id/mds2-2808
License https://www.nist.gov/open/license
Program Code 006:045
Source Datajson Identifier True
Source Hash d02f5079f2be66d79fb3e56f58c6fbd8f4e96580
Source Schema Version 1.1

Didn't find what you're looking for? Suggest a dataset here.