Randomized Battery Usage 2: Room Temperature Random Walk

Published by PCoE | National Aeronautics and Space Administration | Catalog Last Checked: January 03, 2026 at 07:43 PM | Dataset Last Updated: December 09, 2025
This dataset is part of a series of datasets, where batteries are continuously cycled with randomly generated current profiles. Reference charging and discharging cycles are also performed after a fixed interval of randomized usage to provide reference benchmarks for battery state of health. In this dataset, four 18650 Li-ion batteries (Identified as RW3, RW4, RW5 and RW6) were continuously operated by repeatedly charging them to 4.2V and then discharging them to 3.2V using a randomized sequence of discharging currents between 0.5A and 4A. This type of discharging profile is referred to here as random walk (RW) discharging. After every fifty RW cycles a series of reference charging and discharging cycles were performed in order to provide reference benchmarks for battery state health.

Resources

1 resource available

  • Battery_Uniform_Distribution_Discharge_Room_Temp_DataSet_2Post.zip

    ZIP

Find Related Datasets

Search by Tags

Click any tag below to search for similar datasets

data.gov

An official website of the GSA's Technology Transformation Services

Looking for U.S. government information and services?