Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits
Resources
10 resources available
-
Phased Deep Retrofit Field Monitoring Data
HTML -
Phased Retrofits in Existing Homes in Florida Phase I - Shallow and Deep Retrofits
PDF -
pdr7 Existing w_ Min Replace.xml
XML -
pdr7 deep.xml
XML -
PDR Specs and Measures 7-26-16.xlsx
XLSX -
PDR House characteristics.xlsx
XLSX -
pdr39 Existing w_ Min Replace.xml
XML -
pdr39 shallow.xml
XML -
pdr39 deep.xml
XML -
pdr7 shallow.xml
XML
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[ "019:20" ] |
| contactPoint |
{ "fn": "David Beal", "@type": "vcard:Contact", "hasEmail": "mailto:david@fsec.ucf.edu" } |
| dataQuality |
true
|
| description | The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit-shallow and deep-with savings levels that approach the Building America program goal of reducing whole-house energy use by 40%. Home 7 - Merritt Island, FL 32952 Home 39 - Palm Bay, FL 32907 - BEOpt 2.1.0.2 |
| distribution |
[ { "@type": "dcat:Distribution", "title": "Phased Deep Retrofit Field Monitoring Data", "format": "HTML", "accessURL": "http://www.infomonitors.com/pdr/", "mediaType": "text/html", "description": "Detailed, real-time sub-metered data of 62 homes in Florida pre- and post-retrofit." }, { "@type": "dcat:Distribution", "title": "Phased Retrofits in Existing Homes in Florida Phase I - Shallow and Deep Retrofits", "format": "pdf", "accessURL": "https://www.nrel.gov/docs/fy16osti/65327.pdf", "mediaType": "application/pdf", "description": "DOE Report" }, { "@type": "dcat:Distribution", "title": "pdr7 Existing w_ Min Replace.xml", "format": "xml", "mediaType": "text/xml", "description": "BEopt version 2.1.0.2", "downloadURL": "https://data.openei.org/files/5220/pdr7-existing-w-min-replace.xml" }, { "@type": "dcat:Distribution", "title": "pdr7 deep.xml", "format": "xml", "mediaType": "text/xml", "description": "Deep retrofit of PDR House 7, BEopt 2.1.0.2", "downloadURL": "https://data.openei.org/files/5220/pdr7-deep.xml" }, { "@type": "dcat:Distribution", "title": "PDR Specs and Measures 7-26-16.xlsx", "format": "xlsx", "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", "description": "Home Data summary and measurements", "downloadURL": "https://data.openei.org/files/5220/PDR%20Specs%20and%20Measures%207-26-16%20%281%29.xlsx" }, { "@type": "dcat:Distribution", "title": "PDR House characteristics.xlsx", "format": "xlsx", "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", "description": "Housing Information for the PDR repository ", "downloadURL": "https://data.openei.org/files/5220/PDR%20House%20characteristics.xlsx" }, { "@type": "dcat:Distribution", "title": "pdr39 Existing w_ Min Replace.xml", "format": "xml", "mediaType": "text/xml", "description": "Phased Deep Retrofit Home 39 as found, BEopt 2.1.0.2", "downloadURL": "https://data.openei.org/files/5220/pdr39-existing-w-min-replace.xml" }, { "@type": "dcat:Distribution", "title": "pdr39 shallow.xml", "format": "xml", "mediaType": "text/xml", "description": "Phased Deep Retrofit House 39 Shallow retrofit, BEopt 2.1.0.2", "downloadURL": "https://data.openei.org/files/5220/pdr7-shallow_2.xml" }, { "@type": "dcat:Distribution", "title": "pdr39 deep.xml", "format": "xml", "mediaType": "text/xml", "description": "Phased Deep Retrofit House 39 deep retrofit, BEopt 2.1.0.2", "downloadURL": "https://data.openei.org/files/5220/pdr39-deep.xml" }, { "@type": "dcat:Distribution", "title": "pdr7 shallow.xml", "format": "xml", "mediaType": "text/xml", "description": "Shallow retrofit of PDR house 7 BEopt 2.1.0.2", "downloadURL": "https://data.openei.org/files/5220/pdr7-shallow.xml" } ] |
| DOI | 10.25984/2204241 |
| identifier | https://data.openei.org/submissions/5220 |
| issued | 2016-04-27T06:00:00Z |
| keyword |
[ "BuildingAmerica", "building america", "community", "cost effectiveness", "deep energy retrofit", "domestic hot water systems", "existing home", "heat pump water heater", "humidity", "hvac", "lighting", "phased deep retrofit", "pool pumps", "residential", "shallow retrofits" ] |
| landingPage | https://data.openei.org/submissions/5220 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-11-01T16:41:53Z |
| programCode |
[ "019:002" ] |
| projectNumber | FY15 AOP 1.9.1.19 |
| projectTitle | Building America |
| publisher |
{ "name": "University of Central Florida - Florida Solar Energy Center", "@type": "org:Organization" } |
| spatial |
"{"type":"Polygon","coordinates":[[[-83.39573593750004,24.747040690924937],[-78.9683234375,24.747040690924937],[-78.9683234375,28.762145278772028],[-83.39573593750004,28.762145278772028],[-83.39573593750004,24.747040690924937]]]}"
|
| title | Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits |