Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support
Resources
5 resources available
-
Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support
PDF -
My Design - PV.xml
XML -
Completed front elevation 2.jpg
JPG -
TO5 3.3.3_Monitoring Data.dat
DAT -
TO5 3.3.3_BEopt.BEopt.beopt
BEOPT
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[ "019:20" ] |
| contactPoint |
{ "fn": "Ari Rapport", "@type": "vcard:Contact", "hasEmail": "mailto:arapport@ibacos.com" } |
| dataQuality |
true
|
| description | This project was created from a partnership between the U.S. Department of Energy's (DOE's) Building America research team, IBACOS, Inc., and a production builder of high-performance homes called Imagine Homes, which is located in San Antonio, Texas-a hot-humid climate. The primary purpose of this project was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system in maintaining uniform comfort in an occupied test house. My Design - PV: Test house design characteristics, with installed PV system DESIGN - Occupied Test House with PV: Design used for one occupied test house including PV STRUCTURE - Platinum Court San Antonio, TX: Occupied test house in 2013 |
| distribution |
[ { "@type": "dcat:Distribution", "title": "Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support", "format": "pdf", "accessURL": "https://www.nrel.gov/docs/fy17osti/64855.pdf", "mediaType": "application/pdf", "description": "DOE Report" }, { "@type": "dcat:Distribution", "title": "My Design - PV.xml", "format": "xml", "mediaType": "text/xml", "description": "BEopt (v 2.0.0.6) design output.", "downloadURL": "https://data.openei.org/files/5270/my-design---pv.xml" }, { "@type": "dcat:Distribution", "title": "Completed front elevation 2.jpg", "format": "jpg", "mediaType": "image/jpeg", "description": "Front elevation of the test house.", "downloadURL": "https://data.openei.org/files/5270/completed-front-elevation-2.jpg" }, { "@type": "dcat:Distribution", "title": "TO5 3.3.3_Monitoring Data.dat", "format": "dat", "mediaType": "text/html", "description": "Monitoring data - time series", "downloadURL": "https://data.openei.org/files/5270/TO5%203.3.3_Monitoring%20Data.dat" }, { "@type": "dcat:Distribution", "title": "TO5 3.3.3_BEopt.BEopt.beopt", "format": "beopt", "mediaType": "application/octet-stream", "description": "This is the BEopt file for the 2013 Imagine Test House. Version 2.2.0.1 was used. The last Design tab, "2013 Test House (++MSHP)," includes the mini-split heat pump in the options. This model represents the builder standard construction practices against the test house with costs included from the builder.", "downloadURL": "https://data.openei.org/files/5270/to5-3.3.3beopt.beopt" } ] |
| DOI | 10.25984/2204237 |
| identifier | https://data.openei.org/submissions/5270 |
| issued | 2016-04-27T06:00:00Z |
| keyword |
[ "BuildingAmerica", "Zero energy ready home", "building america", "existing home", "hot humid", "indoor air handling unit", "multihead mini-split heat pump", "residential", "single family detached", "spray foam insulation", "vented attic assemble" ] |
| landingPage | https://data.openei.org/submissions/5270 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-11-01T16:41:17Z |
| programCode |
[ "019:000", "019:002" ] |
| projectNumber | FY16 AOP 1.9.1.19 |
| projectTitle | Building America |
| publisher |
{ "name": "Ibacos Innovation", "@type": "org:Organization" } |
| spatial |
"{"type":"Polygon","coordinates":[[[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252]]]}"
|
| title | Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support |