Lab-based multi-wavelength EUV diffractometry for critical dimension metrology
Resources
18 resources available
-
Resource 1
CSV -
Resource 2
TXT -
Resource 3
CSV -
Resource 4
TXT -
Resource 5
CSV -
Resource 6
TXT -
Resource 7
CSV -
Resource 8
TXT -
Analysis
BIN -
BundayLS_fullheight
BIN -
FitMeMasked
PYTH -
README
TXT -
README_Fits
TXT -
fit_jac
BIN -
fit_x
BIN -
minimizer_base_masked
PYTH -
optical_files/SiO2_interpolated_PALIK
TXT -
optical_files/Silicon_interpolated_PALIK
TXT
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| accrualPeriodicity | irregular |
| bureauCode |
[ "006:55" ] |
| contactPoint |
{ "fn": "Bryan Barnes", "hasEmail": "mailto:bryan.barnes@nist.gov" } |
| description | This data set provides the measurement data from EUV diffractometry, simulated fits to these data, and parametric values and uncertainties from these fits as first reported in Barnes et al., "Lab-based multi-wavelength EUV diffractometry for critical dimension metrology", Proc. SPIE 134261V (2025). These values and uncertainties for parametric geometries have been determined from these EUV diffractometry data using a tabletop coherent high- harmonic generation (HHG) source for four line-space arrays with CDs below 50 nm. An EUV imaging reflectometer has captured the 0th order reflection and the 1st order diffraction intensities as functions of grazing angle. The 1st order intensities are functions of five wavelengths from the spectral comb of this HHG source. Fits to these data using rigorous couple-wave analysis (RCWA) electromagnetic simulations yield parametric values and uncertainties. EUV diffractometry simulations match well in general with the measured data after accounting for cross-sectional geometry and experimental conditions. |
| distribution |
[ { "mediaType": "text/csv", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L50P100_full.csv" }, { "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L50P100_full.csv.sha256" }, { "mediaType": "text/csv", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L52P104_full.csv" }, { "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L52P104_full.csv.sha256" }, { "mediaType": "text/csv", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L55P110_full.csv" }, { "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L55P110_full.csv.sha256" }, { "mediaType": "text/csv", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L57P114_full.csv" }, { "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/ark:/88434/mds2-3843/FinalData/L57P114_full.csv.sha256" }, { "title": "Analysis", "mediaType": "application/octet-stream", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/Analysis.ipynb" }, { "title": "BundayLS_fullheight", "mediaType": "application/octet-stream", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/BundayLS_fullheight" }, { "title": "FitMeMasked", "mediaType": "text/x-python", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/FitMeMasked.py" }, { "title": "README", "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/README.txt" }, { "title": "README_Fits", "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/README_Fits.txt" }, { "title": "fit_jac", "mediaType": "application/octet-stream", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/fit_jac.npy" }, { "title": "fit_x", "mediaType": "application/octet-stream", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/fit_x.npy" }, { "title": "minimizer_base_masked", "mediaType": "text/x-python", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/minimizer_base_masked.py" }, { "title": "optical_files/SiO2_interpolated_PALIK", "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/optical_files%2FSiO2_interpolated_PALIK.txt" }, { "title": "optical_files/Silicon_interpolated_PALIK", "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/mds2-3843/optical_files%2FSilicon_interpolated_PALIK.txt" } ] |
| identifier | ark:/88434/mds2-3843 |
| issued | 2025-09-18 |
| keyword |
[ "EUV diffractometry", "EUV scatterometry", "extreme ultraviolet (EUV)" ] |
| landingPage | https://data.nist.gov/od/id/mds2-3843 |
| language |
[ "en" ] |
| license | https://www.nist.gov/open/license |
| modified | 2025-07-10 00:00:00 |
| programCode |
[ "006:045" ] |
| publisher |
{ "name": "National Institute of Standards and Technology", "@type": "org:Organization" } |
| references |
[ "https://doi.org/10.1117/12.3050342" ] |
| theme |
[ "Manufacturing:Process measurement and control", "Metrology:Dimensional metrology", "Nanotechnology:Nanometrology" ] |
| title | Lab-based multi-wavelength EUV diffractometry for critical dimension metrology |