Josephson arbitrary waveform synthesizer for ac voltage calibration, CPEM 2022
Resources
5 resources available
-
Figure 1
CSV -
Figure 2
CSV -
Figure 3
CSV -
Figure 4
CSV -
Readme
TEXT/PLAIN
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[ "006:55" ] |
| contactPoint |
{ "fn": "Alain Rufenacht", "hasEmail": "mailto:alain.rufenacht@nist.gov" } |
| description | This is the dataset for 4 publishable figures in 2 page abstracted titled "Josephson arbitrary waveform synthesizer for ac voltage calibrations" submitted to the Conference on Precision Electromagnetic Measurements, CPEM 2022. QLR=Quantum Locking Range.Fig. 1. QLR (2 V rms waveforms) as a function of the dc bias current offset in all 4 arrays of Bias 1.Fig. 2. QLR (2 V rms waveforms) as a function of the compensation current amplitude in all 4 arrays of Bias 1.Fig. 3. QLR (2 V rms waveform) as a function of the pulse amplitude on Bias 1 or Bias 2 high-speed current pulse channel.Fig. 4. QLR (2 V rms waveforms) as a function of the compensation current phase in all 4 arrays of Bias 1. |
| distribution |
[ { "title": "Figure 1", "format": "CSV", "mediaType": "text/csv", "description": "Fig. 1. QLR (2 V rms waveforms) as a function of the dc bias current offset in all 4 arrays of Bias 1.", "downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig1%20Bias%20Current%20DC%20Offset.csv" }, { "title": "Figure 2", "format": "CSV", "mediaType": "text/csv", "description": "Fig. 2. QLR (2 V rms waveforms) as a function of the compensation current amplitude in all 4 arrays of Bias 1.", "downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig2%20Compensation%20Amplitude%20Dither.csv" }, { "title": "Figure 3", "format": "CSV", "mediaType": "text/csv", "description": "Fig. 3. QLR (2 V rms waveform) as a function of the pulse amplitude on Bias 1 or Bias 2 high-speed current pulse channel.", "downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig3%20Pulse%20Amplitude%20Dither.csv" }, { "title": "Figure 4", "format": "CSV", "mediaType": "text/csv", "description": "Fig. 4. QLR (2 V rms waveforms) as a function of the compensation current phase in all 4 arrays of Bias 1.", "downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig4%20Compensation%20Phase%20Dither.csv" }, { "title": "Readme", "mediaType": "text/plain", "downloadURL": "https://data.nist.gov/od/ds/mds2-2682/2682_README.txt" } ] |
| identifier | ark:/88434/mds2-2682 |
| issued | 2022-07-20 |
| keyword |
[ "Josephson arrays", "digital-analog conversion", "quantization", "signal synthesis", "standards", "superconducting integrated circuits", "voltage measurement" ] |
| language |
[ "en" ] |
| license | https://www.nist.gov/open/license |
| modified | 2022-06-14 00:00:00 |
| programCode |
[ "006:045" ] |
| publisher |
{ "name": "National Institute of Standards and Technology", "@type": "org:Organization" } |
| theme |
[ "Metrology:Electrical/electromagnetic metrology", "Standards:Reference instruments" ] |
| title | Josephson arbitrary waveform synthesizer for ac voltage calibration, CPEM 2022 |