GC-MS Surface Response Data for Instrument Optimization
Resources
1 resource available
-
GC-MS Surface Response Data for Instrument Optimization
FILE
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[ "000:00" ] |
| contactPoint |
{ "fn": "Stephanie Gamble", "@type": "vcard:Contact", "hasEmail": "mailto:stephanie.gamble@srnl.doe.gov" } |
| description | The objective of this example case was to maximize peak height and minimize peak width of 11 iodinated standards analyzed using gas chromatography-mass spectrometry (GC-MS). Once the significant (or most significant) parameters have been determined in a prior screening experiment, another set of experiments must be designed in which a response surface objective experiment is performed to collect data for optimization. In this example case, surface response experiments were performed using a 3-level Box-Behnken design in which each statistically significant parameter (e.g. split ratio, carrier gas flow rate, oven temperature ramp rate, and capillary column film thickness) was assigned a “low”, “middle”, and “high” value. For these experiments, the three nonsignificant parameters, inlet temperature, injection volume, and auxiliary line temperature, were fixed at 200 °C, 2 μL, and 280 °C, respectively. The experiments were conducted in the same manner as described in the screening experiments section. The attached CSV files contain the Box-Behnken design (bbd.csv), the raw chromatographic data for the 25 distinct methods (Method #.csv), and the retention times (bb_rts.csv) for each iodinated standard. |
| distribution |
[ { "@type": "dcat:Distribution", "title": "GC-MS Surface Response Data for Instrument Optimization", "accessURL": "https://figshare.com/articles/dataset/GC-MS_Surface_Response_Data_for_Instrument_Optimization/28636013", "description": "The objective of this example case was to maximize peak height and minimize peak width of 11 iodinated standards analyzed using gas chromatography-mass spectrometry (GC-MS). Once the significant (or most significant) parameters have been determined in a prior screening experiment, another set of experiments must be designed in which a response surface objective experiment is performed to collect data for optimization. In this example case, surface response experiments were performed using a 3-level Box-Behnken design in which each statistically significant parameter (e.g. split ratio, carrier gas flow rate, oven temperature ramp rate, and capillary column film thickness) was assigned a “low”, “middle”, and “high” value. For these experiments, the three nonsignificant parameters, inlet temperature, injection volume, and auxiliary line temperature, were fixed at 200 °C, 2 μL, and 280 °C, respectively. The experiments were conducted in the same manner as described in the screening experiments section. The attached CSV files contain the Box-Behnken design (bbd.csv), the raw chromatographic data for the 25 distinct methods (Method #.csv), and the retention times (bb_rts.csv) for each iodinated standard." } ] |
| identifier | SRNL-STI-2023-00543 |
| issued | 2025-04-21 |
| keyword |
[ "Analytical spectrometry", "Instrumental methods", "Separation Science" ] |
| landingPage | https://figshare.com/articles/dataset/GC-MS_Surface_Response_Data_for_Instrument_Optimization/28636013 |
| language |
[ "en-US" ] |
| license | https://www.gnu.org/licenses/gpl-3.0.html |
| modified | 2025-08-14T17:20:47.074Z |
| programCode |
[ "000:000" ] |
| publisher |
{ "name": "Savannah River National Laboratory (DOE)", "@type": "org:Organization" } |
| references |
[ "https://doi.org/10.1021/acs.analchem.3c05763" ] |
| rights |
"true"
|
| title | GC-MS Surface Response Data for Instrument Optimization |