Experimental Results for Heat-Pulse Flowmeter

Published by U.S. Geological Survey | Department of the Interior | Catalog Last Checked: May 05, 2026 at 09:18 PM | Dataset Last Updated: November 22, 2021 at 12:00 AM
The heat-pulse flowmeter (HH) used in this testing is a KVA Model 200 system. The instrument computes groundwater vectors from heat arrival and decay in an array of four thermistors that surround a single heat source. An external compass attached to the top of the deployment system is used to orient the flowmeter in the borehole. The HH measured groundwater velocity and flow in the x-y plane. Fuzzy packers were filled with 0.08-inch diameter glass beads for all tests. The HH thermistors were centered over the simulated fracture during measurements. One to four measurements were made with the HH for each simulated flow.