Skip to main content
U.S. flag

An official website of the United States government

This site will undergo scheduled maintenance on 2026-05-20 Wednesday from 3:30 PM to 4:30 PM EDT.
During this time, the site will be unavailable. We apologize for any inconvenience.

Dynamic Range by Design in OTA EVM measurements

Published by National Institute of Standards and Technology | National Institute of Standards and Technology | Catalog Last Checked: August 02, 2025 at 03:09 PM | Dataset Last Updated: April 22, 2023
We present an experimental approach to design an over-the-air (OTA) millimeter-wave system for measuring error vector magnitude (EVM) with associated uncertainties that include correlations and nonlinearities. Our approach uses a variable waveguide attenuator at the output of a modulated-signal source at 44 GHz and provides traceable measurements on a calibrated equivalent-time sampling oscilloscope. The conductor-based EVM measurements and associated uncertainties presented here serve as a baseline for the eventual OTA-based EVM. We also discuss a noise based EVM estimation technique as a simple tool for planning OTA EVM measurements, but without a complete knowledge of measurement uncertainties.

Resources