Skip to main content
U.S. flag

An official website of the United States government

Dataset in support of publication : Sensitivity Comparison of Rydberg Atom-Based Radio-Frequency Electric Field Detection: Ionization Current Versus Optical Readout

Published by National Institute of Standards and Technology | National Institute of Standards and Technology | Catalog Last Checked: September 02, 2026 at 07:19 PM | Dataset Last Updated: August 04, 2025
We investigate a technique for detecting radio-frequency (RF) electric fields in a Cesium (Cs) vapor cell at room temperature by collecting charge from ionized Rydberg atoms and compare its performance with the established method of electromagnetically induced transparency (EIT). By applying a known RF field, we measure the response from both the electrical (ionization current-based) and optical (EIT-based) readouts. The ionization current-based method yields a sensitivity of 22.4~$\mu$Vm$^{-1}$Hz$^{-1/2}$, while the EIT-based method achieves 3.7~$\mu$Vm$^{-1}$Hz$^{-1/2}$. The sensitivity of the ionization current-based method is limited by thermal noise arising from a 2.2~k$\Omega$ resistance between the collection electrodes, attributed to a thin Cs film on the inner surfaces of the vapor cell. Controlling or eliminating the Cs layer can significantly improve the sensitivity of this ionization approach.

Resources

15 resources available

  • Beat Note Amplitude vs. Input Signal RF Power from EIT

    6
  • Beat Note Amplitude vs. Input Signal RF Power from Ionization

    6
  • EIT Spectra for Varying Coupling Rabi Frequencies

    UNIT
  • EIT Spectra for Varying Probe Rabi Frequencies

    UNIT
  • EIT-AT and Ionization Spectra at Various RF Signal Powers

    UNIT
  • EIT and Ionization Full Width at Half Maximum (FWHM) and Amplitude vs. Coupling Rabi Frequency

    UNIT
  • EIT and Ionization Full Width at Half Maximum (FWHM) and Amplitude vs. Probe Rabi Frequency

    UNIT
  • Ionization Spectra for Varying Coupling Rabi Frequencies

    UNIT
  • Ionization Spectra for Varying Probe Rabi Frequencies

    UNIT
  • Measured RF Electric Field Amplitude vs. Square Root of Input Signal RF Power

    M
  • Noise Spectra for EIT Measurements

    6
  • Noise Spectra for Ionization Measurements

    7
  • Sensitivity as a Function of Coupling Rabi Frequency

    5
  • Sensitivity as a Function of Probe Rabi Frequency

    5
  • Read me file for data set

    TXT

Find Related Datasets

Search by Tags

Click any tag below to search for similar datasets

data.gov

An official website of the GSA's Technology Transformation Services

Looking for U.S. government information and services?
Visit USA.gov