Data from Fire Safety Challenges of Tall Wood Buildings - Phase 2: Task 3 - Cross Laminated Timber Compartment Fire Tests

Metadata Updated: April 11, 2024

This study quantifies the contribution of CLT building elements to compartment fires and characterizes the effect of gypsum board on delaying or preventing involvement of the CLT in the fire under varied ventilation conditions. Six compartments (9.1 m long x 4.6 m wide x 2.7 m high) were assembled out of prefabricated CLT panels. Each panel was factory assembled using five plies of 35 mm thick lumber for a total thickness of 175 mm. A polyurethane adhesive was used to hold the plies together. The compartment had a rough opening in Wall W2 (front) of 1.8 m wide x 2.0 m high in four tests and 3.6 m wide x 2.0 m high in two tests. The inside of the compartments was fully or partially lined using multiple layers of 15.9-mm thick Type X gypsum board. Real residential contents and furnishings were used to provide a fire load density of 550 MJ/m2. The fire tests were conducted without sprinklers and without firefighting intervention.The dataset includes Excel files with the data from each test, as well as videos and 360 degree images.

Access & Use Information

Public: This dataset is intended for public access and use. License: See this page for license information.

Downloads & Resources

References

https://www.nist.gov/system/files/documents/2018/02/14/task_2_3_report_-_clt_compartment_fire_tests.pdf

Dates

Metadata Created Date March 11, 2021
Metadata Updated Date April 11, 2024
Data Update Frequency irregular

Metadata Source

Harvested from NIST

Additional Metadata

Resource Type Dataset
Metadata Created Date March 11, 2021
Metadata Updated Date April 11, 2024
Publisher National Institute of Standards and Technology
Maintainer
Identifier 5CF421B31BE80304E0531A57068197E41874
Language en
Data Last Modified 2018-02-15 00:00:00
Category Buildings and Construction:Structural engineering, Fire:Structural fire resistance, Buildings and Construction:Building materials
Public Access Level public
Data Update Frequency irregular
Bureau Code 006:55
Metadata Context https://project-open-data.cio.gov/v1.1/schema/data.json
Schema Version https://project-open-data.cio.gov/v1.1/schema
Catalog Describedby https://project-open-data.cio.gov/v1.1/schema/catalog.json
Harvest Object Id 79698b42-f195-41d2-99d0-e05b99f5958e
Harvest Source Id 74e175d9-66b3-4323-ac98-e2a90eeb93c0
Harvest Source Title NIST
Homepage URL https://data.nist.gov/od/id/5CF421B31BE80304E0531A57068197E41874
License https://www.nist.gov/open/license
Program Code 006:045
Related Documents https://www.nist.gov/system/files/documents/2018/02/14/task_2_3_report_-_clt_compartment_fire_tests.pdf
Source Datajson Identifier True
Source Hash 54f8e46c9653239ac2b09e6ab548a204309e954ffe5d310cccea64b4ea0ce5b5
Source Schema Version 1.1

Didn't find what you're looking for? Suggest a dataset here.