BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of Heat Pump and Air Conditioner
Access & Use Information
Downloads & Resources
-
Test_Matrix file describes all the indoor and...
Test_Matrix file describes all the indoor and outdoor test conditions for...
-
AC tested at outdoor temperature 23.9C / 75F...BIN
AC tested at outdoor temperature 23.9C / 75F for setpoints 72F, 68F
-
AC tested at outdoor temperature 29.4C / 85F...BIN
AC tested at outdoor temperature 29.4C / 85F for setpoints 76F, 72F, 68F
-
AC tested at outdoor temperature 35C / 95F for...BIN
AC tested at outdoor temperature 35C / 95F for setpoints 76F, 72F, 68F
-
AC tested at outdoor temperature 40.5C / 105F...BIN
AC tested at outdoor temperature 40.5C / 105F for setpoints 76F, 72F, 68F
-
AC tested at outdoor temperature 46.1C / 115F...BIN
AC tested at outdoor temperature 46.1C / 115F for setpoints 76F, 72F, 68F
-
HP tested in heating mode with backup...BIN
HP tested in heating mode with backup auxiliary heater at outdoor temperature...
-
HP tested in heating mode with backup...BIN
HP tested in heating mode with backup auxiliary heater at outdoor temperature...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature 12.8C / 55F for setpoints...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature -15C / 5F for setpoint 72F
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature -15C / 5F for setpoints 64F,...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature -9.4C / 15F for setpoints...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature -3.9C / 25F for setpoints...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature -3.9C / 25F for setpoints 64F
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature 1.7C / 35F for setpoints...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature 7.2C / 45F for setpoints...
-
HP tested in heating mode at outdoor...BIN
HP tested in heating mode at outdoor temperature 7.2C / 45F for setpoints 64F
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 46.1C / 115F for setpoints 76F
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 46.1C / 115F for setpoint 72F
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 46.1C / 115F for setpoint 68F
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 40.5C / 105F for setpoint 68F
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 40.5C / 105F for setpoints...
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 35C / 95F for setpoints 76F,...
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 29.4C / 85F for setpoints...
-
HP tested in cooling mode at outdoor...BIN
HP tested in cooling mode at outdoor temperature 23.9C / 75F for setpoints...
-
Landing PageLanding Page
Dates
Metadata Created Date | January 12, 2025 |
---|---|
Metadata Updated Date | January 20, 2025 |
Metadata Source
- Data.json Data.json Metadata
Harvested from OpenEI data.json
Additional Metadata
Resource Type | Dataset |
---|---|
Metadata Created Date | January 12, 2025 |
Metadata Updated Date | January 20, 2025 |
Publisher | National Renewable Energy Laboratory |
Maintainer | |
Identifier | https://data.openei.org/submissions/8292 |
Data First Published | 2024-09-10T16:49:42Z |
Data Last Modified | 2024-12-18T21:46:23Z |
Public Access Level | public |
Bureau Code | 019:20 |
Metadata Context | https://openei.org/data.json |
Metadata Catalog ID | https://openei.org/data.json |
Schema Version | https://project-open-data.cio.gov/v1.1/schema |
Catalog Describedby | https://project-open-data.cio.gov/v1.1/schema/catalog.json |
Data Quality | True |
Datagov Dedupe Retained | 20250120171954 |
Harvest Object Id | e33ee2f4-4b44-40b7-b3e6-d0cc0411d0d4 |
Harvest Source Id | 7cbf9085-0290-4e9f-bec1-91653baeddfd |
Harvest Source Title | OpenEI data.json |
Homepage URL | https://data.nrel.gov/submissions/246 |
License | https://creativecommons.org/licenses/by/4.0/ |
Program Code | 019:002, 019:000 |
Projectnumber | 3.2.6.105 |
Projecttitle | A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset |
Source Datajson Identifier | True |
Source Hash | 0edcd073edeaf362fb0838162e011dcda310e2e12afedc49c1e3cf99c954f96a |
Source Schema Version | 1.1 |
Didn't find what you're looking for? Suggest a dataset here.