  "description": "The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Connecticut, to evaluate and implement a cost-effective solution package that met the requirements of 30% source energy savings compared to the pre-retrofit performance. This home had already been updated aesthetically (kitchen and bathrooms), so the owners wanted the energy-efficiency measures to be as non-disruptive to the interior finishes as possible.",
  "distribution": [
    {
      "@type": "dcat:Distribution",
      "accessURL": "https://www.nrel.gov/docs/fy15osti/64353.pdf",
      "description": "DOE Report",
      "format": "pdf",
      "mediaType": "application/pdf",
      "title": "Retrofitting a 1960s Split-Level Cold-Climate Home"
    },
    {
      "@type": "dcat:Distribution",
      "description": "BEopt File for home performance characteristics ",
      "downloadURL": "https://data.openei.org/files/4670/bpc-green-builders.beopt",
      "format": "beopt",
      "mediaType": "application/octet-stream",
      "title": "BPC-Green-builders.beopt"
    },
    {
      "@type": "dcat:Distribution",
      "description": "BEopt File for home performance characteristics",
      "downloadURL": "https://data.openei.org/files/4670/37oakretrofit.beopt",
      "format": "beopt",
      "mediaType": "application/octet-stream",
      "title": "37OakRetrofit.beopt"
    }
  ],
  "identifier": "https://data.openei.org/submissions/4670",
  "issued": "2016-04-27T06:00:00Z",
  "keyword": [
    "BuildingAmerica",
    "airtightness",
    "building america",
    "cellulose",
    "closed-cell spray foam insulation",
    "cold",
    "cost effectiveness",
    "existing home",
    "natural gas condensing tankless boiling",
    "occupied home",
    "residential",
    "retrofit",
    "thermal resistance",
    "unvented attic",
    "utility bill validation"
  ],
  "landingPage": "https://data.openei.org/submissions/4670",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "modified": "2023-11-01T16:43:41Z",
  "programCode": [
    "019:000",
    "019:002"
  ],
  "projectNumber": "FY15 AOP 1.9.1.19",
  "projectTitle": "Building America",
  "publisher": {
    "@type": "org:Organization",
    "name": "Steven Winter Associates of the Consortium for Advanced Residential Buildings"
  },
  "spatial": "{\"type\":\"Polygon\",\"coordinates\":[[[-73.3579,41.1415],[-73.3579,41.1415],[-73.3579,41.1415],[-73.3579,41.1415],[-73.3579,41.1415]]]}",
  "title": "Retrofitting a 1960s Split-Level Cold-Climate Home"
}