{"@type": "dcat:Dataset", "accessLevel": "public", "accrualPeriodicity": "irregular", "bureauCode": ["006:55"], "contactPoint": {"fn": "Lisa Choe", "hasEmail": "mailto:lisa.choe@nist.gov"}, "description": "Experimental fire tests were conducted on four 12.8 m long steel-concrete composite floor beam assemblies with varying end support conditions, including two types of simple shear connections (shear tabs or welded-bolted double angles) and slab end continuity. Each specimen was constructed as a partially-composite beam, consisting of a lightweight concrete slab on formed metal decking supported by a W18x35 steel beam acting compositely via 19 mm diameter headed stud anchors spaced 305 mm. While resisting an ASCE 7-specified gravity load using hydraulic actuators, each specimen was exposed to a structurally significant  fire that was produced using three natural gas-fueled burners distributed on the floor of the test compartment with the maximum heat release rate of 4 MW. Imposed mechanical loading and fire characteristics, thermal and structural responses, and structural failure modes of the specimens were studied.", "distribution": [{"accessURL": "https://doi.org/10.18434/M32181", "title": "DOI Access for Dataset from Steel-Concrete Composite Floor Systems Subject to Fire - Phase 1"}], "identifier": "ark:/88434/mds2-2181", "issued": "2020-03-31", "keyword": ["NFRL", "Temperature effects", "compartment fires", "composite beams", "steel connections"], "landingPage": "https://www.nist.gov/el/fire-research-division-73300/national-fire-research-laboratory-73306/steel-concrete-composite-0", "language": ["en"], "license": "https://www.nist.gov/open/license", "modified": "2020-01-31 00:00:00", "programCode": ["006:045"], "publisher": {"@type": "org:Organization", "name": "National Institute of Standards and Technology"}, "references": ["https://doi.org/10.6028/NIST.TN.2054", "https://doi.org/10.6028/NIST.TN.2055"], "theme": ["Buildings and Construction:Structural engineering", "Fire:Fire risk reduction", "Fire:Structural fire resistance"], "title": "Dataset from Steel-Concrete Composite Floor Systems Subject to Fire - Phase 1"}