{"accessLevel": "public", "bureauCode": ["010:12"], "contactPoint": {"@type": "vcard:Contact", "fn": "Tamara N Jeppson", "hasEmail": "mailto:tjeppson@usgs.gov"}, "description": "Laboratory slide-hold-slide tests were conducted in a conventional triaxial deformation configuration on 1-inch diameter cylindrical cores of Westerly granite bisected by a sawcut oriented at 30 degrees from vertical. Tests were conducted at a constant confining pressure of 30 MPa with a 10 MPa pore fluid pressure. The pore fluid was deionized water. Experiments were conducted at temperatures of 22, 100, 200, and 250 degC.", "distribution": [{"@type": "dcat:Distribution", "accessURL": "https://doi.org/10.5066/P9KNV1J8", "description": "Landing page for access to the data", "format": "XML", "mediaType": "application/http", "title": "Digital Data"}, {"@type": "dcat:Distribution", "description": "The metadata original format", "downloadURL": "https://data.usgs.gov/datacatalog/metadata/USGS.64946e01d34ef77fcb015250.xml", "format": "XML", "mediaType": "text/xml", "title": "Original Metadata"}], "identifier": "http://datainventory.doi.gov/id/dataset/USGS_64946e01d34ef77fcb015250", "keyword": ["USGS:64946e01d34ef77fcb015250", "fluid-rock interactions", "friction", "hydrothermal", "restrengthening"], "modified": "2023-10-10T00:00:00Z", "publisher": {"@type": "org:Organization", "name": "U.S. Geological Survey"}, "spatial": "-122.1729000, 37.4554830, -122.1726750, 37.4557530", "theme": ["geospatial"], "title": "Slide-hold-slide experiments on Westerly Granite at temperatures up to 250  \u00b0C"}