{"@type": "dcat:Dataset", "DOI": "10.25984/2204261", "accessLevel": "public", "bureauCode": ["019:20"], "contactPoint": {"@type": "vcard:Contact", "fn": "Pat Huelman", "hasEmail": "mailto:Phuelman@umn.edu"}, "dataQuality": true, "description": "This is a repository for all NorthernSTAR Zero Energy Ready certified homes.\n\nAmaris Homes Model Home - St. Paul, MN 55110\nDescription: Model home completed September 2013\nThe DOE Zero Energy Ready Home Case Study looks to study and eventually design zero net energy homes in cold weather climates. These zero net energy homes are referred to as challenge homes. For this challenge home, Amaris Homes is working with the DOE in St. Paul, Minnesota. The household located at MN 55110 acts as the Amaris Challenge Home Test. The resources include technical drawings including siding, roofing and Windows.\n\nChristian Builders Challenge Home - House Count: 1 - Otsego, MN 55374\nNeed pictures from builder; This home actually narrowly missed certification under DOE Net Zero Energy Ready Homes. Need building plans and project summary from builder.\n\nDESIGN AND STRUCTURE - Amaris Homes - House Count: 7\nStillwater, MN 55082; Vadnais Heights, MN 55127; Bloomington, MN 55437; Apple Valley, MN 55124; White Bear Lake, MN 55110; Mounds View, MN 55112; Midland, MI 48642;\nDOE Zero Energy Ready Homes", "distribution": [{"@type": "dcat:Distribution", "accessURL": "https://www.energy.gov/sites/default/files/2015/06/f23/ba_case_study_zerh_amaris_homes.pdf", "description": "For this project Amaris worked with U.S. Department of Energy (DOE) team, NorthernSTAR Building America Partnership, to approach zero energy in Minnesota's cold climate using reasonable, cost-effective, and replicable construction materials and practices. The result is a passive solar, super-efficient 3542-ft2 walkout rambler with all the creature comforts.", "format": "pdf", "mediaType": "application/pdf", "title": "DOE Zero Energy Ready Home Case Study - Amaris Custom Homes"}, {"@type": "dcat:Distribution", "accessURL": "https://www.energy.gov/sites/prod/files/2015/10/f27/Amaris_2015_DOE_ZER-HIA_casestudy_PNNL-10-5-15.pdf", "description": "This document further explains Amaris Homes' involvement in the DOE's case study into net zero homes in cold climates. The document includes an explanation of the challenge home project that relates to the technical drawings in this submission.", "format": "pdf", "mediaType": "application/pdf", "title": "DOE ZERH Case Study Amaris Homes Fishers Circle Vadnais Heights MN"}, {"@type": "dcat:Distribution", "description": "BEopt Building File for home performance characteristics", "downloadURL": "https://data.openei.org/files/4603/christiangm1-v2.2-hpxml.xml", "format": "xml", "mediaType": "text/xml", "title": "ChristianGM1 v2.2 hpxml.xml"}, {"@type": "dcat:Distribution", "description": "BEopt Building File for home performance characteristics - Bloomington", "downloadURL": "https://data.openei.org/files/4603/108thgm1-v2.4-hpxml.xml", "format": "xml", "mediaType": "text/xml", "title": "108thGM1 v2.4 hpxml.xml"}, {"@type": "dcat:Distribution", "description": "BEopt Building File for home performance characteristics - Cobblestone", "downloadURL": "https://data.openei.org/files/4603/2936-e-iron-woods-pass-gm1-v2.4-hpxml.xml", "format": "xml", "mediaType": "text/xml", "title": "E Iron Woods Pass GM1 v2.4 hpxml.xml"}, {"@type": "dcat:Distribution", "description": "BEopt Building File for home performance characteristics - Fisher Circle", "downloadURL": "https://data.openei.org/files/4603/549-fischer-circle-gm1-v2.4-hpxml.xml", "format": "xml", "mediaType": "text/xml", "title": "Fischer Circle GM1 v2.4 hpxml.xml"}, {"@type": "dcat:Distribution", "description": "BEopt Building File for home performance characteristics - Oak Bluff", "downloadURL": "https://data.openei.org/files/4603/amarisgm1-v2.2-hpxml.xml", "format": "xml", "mediaType": "text/xml", "title": "AmarisGM1 v2.2 hpxml.xml"}, {"@type": "dcat:Distribution", "description": "BEopt Building File for home performance characteristics - Willow", "downloadURL": "https://data.openei.org/files/4603/115-willowgm1-v2.4-hpxml.xml", "format": "xml", "mediaType": "text/xml", "title": "WillowGM1 v2.4 hpxml.xml"}, {"@type": "dcat:Distribution", "description": "Building Plans - Amaris", "downloadURL": "https://data.openei.org/files/4603/building-plans-amaris-4-11-13-36x24.pdf", "format": "pdf", "mediaType": "application/pdf", "title": "Building Plans Amaris-4-11-13-36x24.pdf"}, {"@type": "dcat:Distribution", "description": "Building Plans - Fisher; 36X24", "downloadURL": "https://data.openei.org/files/4603/14-142-pf-001-Fisher-circle-7.12.14-36x24.pdf", "format": "pdf", "mediaType": "application/pdf", "title": "Fisher-circle-7.12.14.pdf"}, {"@type": "dcat:Distribution", "description": "Building plans - Cobblestone", "downloadURL": "https://data.openei.org/files/4603/01.06.14-lm18-construction-drawings.pdf", "format": "pdf", "mediaType": "application/pdf", "title": "01.06.14 LM18 Construction Drawings.pdf"}, {"@type": "dcat:Distribution", "description": "DHW and in-floor radiant heat boiler - Oak Bluff", "downloadURL": "https://data.openei.org/files/4603/wall-mounted-boiler.jpeg", "format": "jpeg", "mediaType": "application/octet-stream", "title": "Wall Mounted Boiler.jpeg"}, {"@type": "dcat:Distribution", "description": "DOE ZERH case study report - Cobblestone", "downloadURL": "https://data.openei.org/files/4603/doezehcobblestone09-19-140.pdf", "format": "pdf", "mediaType": "application/pdf", "title": "DOE_ZEH_Cobblestone_09-19-14_0.pdf"}, {"@type": "dcat:Distribution", "description": "Each home address is listed with a brief description including house count, last update, last updated by, and notes.", "downloadURL": "https://data.openei.org/files/4603/HouseDescriptions.txt", "format": "txt", "mediaType": "text/plain", "title": "Home Descriptions and Locations.txt"}, {"@type": "dcat:Distribution", "description": "Front (north) elevation - Oak Bluff", "downloadURL": "https://data.openei.org/files/4603/front-elevation.jpeg", "format": "jpeg", "mediaType": "application/octet-stream", "title": "Front Elevation.jpeg"}, {"@type": "dcat:Distribution", "description": "Overhangs deck cantilevers all designed for shading windows", "downloadURL": "https://data.openei.org/files/4603/overhangs-deck-cantelivers-all-designed-for-shading-windows.jpeg", "format": "jpeg", "mediaType": "application/octet-stream", "title": "Rear south elevation - Oak Bluff.jpeg"}, {"@type": "dcat:Distribution", "description": "Picture - Fisher Circle; 1500x1000-72dpi", "downloadURL": "https://data.openei.org/files/4603/549-fisher-cir-vadnais-heights-large-028-549-fisher-cir28-1500x1000-72dpi.jpg", "format": "jpg", "mediaType": "image/jpeg", "title": "Fisher Cir Vadnais Heights-large-028- Fisher Cir28.jpg"}, {"@type": "dcat:Distribution", "description": "Picture - Fisher Circle; 1500x1000-72dpi", "downloadURL": "https://data.openei.org/files/4603/549-fisher-cir-vadnais-heights-large-029-549-fisher-cir29-1500x1000-72dpi.jpg", "format": "jpg", "mediaType": "image/jpeg", "title": "Fisher Cir Vadnais Heights-large-029-Fisher Cir29.jpg"}, {"@type": "dcat:Distribution", "description": "Picture - Fisher Circle; 1500x1000-72dpi", "downloadURL": "https://data.openei.org/files/4603/549-fisher-cir-vadnais-heights-large-030-549-fisher-cir30-1500x1000-72dpi.jpg", "format": "jpg", "mediaType": "image/jpeg", "title": "Fisher Cir Vadnais Heights-large-030-Fisher Cir30.jpg"}, {"@type": "dcat:Distribution", "description": "Utility Bills - Oak Bluff\n", "downloadURL": "https://data.openei.org/files/4603/amaris-yr1-utilitybills.xlsx", "format": "xlsx", "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", "title": "Amaris yr1 utilityBills.xlsx"}], "identifier": "https://data.openei.org/submissions/4603", "issued": "2016-04-27T06:00:00Z", "keyword": ["BuildingAmerica", "DOE Challenge Home", "HERS", "Zero Net Energy Homes", "Zero energy ready home", "building america", "building envelope", "cold", "cost effectiveness", "insulation", "residential", "roofing", "single family detached", "technical drawings", "thermal mass flooring", "windows"], "landingPage": "https://data.openei.org/submissions/4603", "license": "https://creativecommons.org/licenses/by/4.0/", "modified": "2023-11-01T16:43:45Z", "programCode": ["019:000", "019:002"], "projectNumber": "FY13 AOP 1.9.1.19", "projectTitle": "Building America", "publisher": {"@type": "org:Organization", "name": "University of Minnesota - NorthernSTAR Building America Partnership"}, "spatial": "{\"type\":\"Polygon\",\"coordinates\":[[[-93.38505478515626,44.73519168661846],[-92.80285712890628,44.73519168661846],[-92.80285712890628,45.12336658315757],[-93.38505478515626,45.12336658315757],[-93.38505478515626,44.73519168661846]]]}", "title": "NorthernStar Zero Energy Ready Homes"}