{"@type": "dcat:Dataset", "DOI": "10.25984/2204262", "accessLevel": "public", "bureauCode": ["019:20"], "contactPoint": {"@type": "vcard:Contact", "fn": "David Beal", "hasEmail": "mailto:david@fsec.ucf.edu"}, "dataQuality": true, "description": "The Building America Partnership for Improved Residential Construction, formerly the Building America Industrialized Housing Partnership, has worked with several community-scale builders within the hot-humid climate zone to improve performance of production-, or community-scale, housing. Tommy Williams Homes (Gainesville, Florida), LifeStyle Homes (Melbourne, Florida), and Habitat for Humanity (various locations, Florida) have all been continuous partners of the Building America Program. The activities of these partners, described in this report, achieved the Building America goal of 30% whole-house source energy savings using packages adopted at the community scale. For new homes, the reference case is the B10 Benchmark, aligned with 2009 building codes.", "distribution": [{"@type": "dcat:Distribution", "accessURL": "http://www.ba-pirc.org/casestud/pdf/LifeStyle_BusinessCase.pdf", "description": "Business Case Study on LIfeStyle Homes - Lessons Learned and Looking Ahead", "format": "pdf", "mediaType": "application/pdf", "title": "Case Study Zero Net-Energy Homes Production Builder Business Case LifeStyle Homes"}, {"@type": "dcat:Distribution", "accessURL": "http://www.ba-pirc.org/casestud/pdf/TW_BusinessCase.pdf", "description": "Business Case Study on Tommy Williams Homes - Marketing Lessons Learned and Looking Ahead", "format": "pdf", "mediaType": "application/pdf", "title": "Case Study Business Case for High Performance Homes Tommy Williams Homes"}, {"@type": "dcat:Distribution", "accessURL": "https://www.nrel.gov/docs/fy13osti/57823.pdf", "description": "This report describes how these goals were achieved in production-scale homes that were built\ncost effectively at the community scale and modeled to reduce whole-house energy use by 30%\nor more in the hot-humid climate region. Key aspects of this research include determining how to\nevolve existing energy efficiency packages to produce replicable target savings, identifying\nbuilders\u2019 technical assistance needs for implementation and working with them to create\nsustainable quality assurance mechanisms, and documenting commercial viability through\nneutral cost analysis and market acceptance. This report documents barriers that builders\novercame and the approaches they implemented to accomplish Building America Program goals\nthat have not already been described in previous reports.", "format": "pdf", "mediaType": "application/pdf", "title": "Approaches to 30 Energy Savings at the Community Scale in the Hot-Humid Climate"}, {"@type": "dcat:Distribution", "description": "Lifestyle Home used for 30% reprot, BEOpt 2.1.0.2", "downloadURL": "https://data.openei.org/files/4588/lifestyle.xml", "format": "xml", "mediaType": "text/xml", "title": "LifeStyle Homes Report Model.xml"}, {"@type": "dcat:Distribution", "description": "Lifestyle Homes BA10 Benchmark home", "downloadURL": "https://data.openei.org/files/4588/lifestyle-b10-benchmark.xml", "format": "xml", "mediaType": "text/xml", "title": "LifeStyle Model BA10 Benchmark.xml"}, {"@type": "dcat:Distribution", "description": "Tommy Williams Homes Beckton Model Homes with attic ducts and a run-time vent (typical for report time frame)", "downloadURL": "https://data.openei.org/files/4588/twh-run-time.xml", "format": "xml", "mediaType": "text/xml", "title": "Tommy Williams Homes Model with Attic Ducts.xml"}, {"@type": "dcat:Distribution", "description": "Tommy Williams Homes Beckton Model with attic ducts and 100% ASHREA 62.2 exhaust venting", "downloadURL": "https://data.openei.org/files/4588/twh-exhaust-100ashrae.xml", "format": "xml", "mediaType": "text/xml", "title": "Tommy Williams Homes Model with ASHRAE.xml"}, {"@type": "dcat:Distribution", "description": "Tommy Williams Homes Beckton Model with interior ducts and a run-time vent, as built 2013-14", "downloadURL": "https://data.openei.org/files/4588/twh-run-time-and-interior-ducts.xml", "format": "xml", "mediaType": "text/xml", "title": "Tommy Williams Homes Model with Interior Ducts.xml"}, {"@type": "dcat:Distribution", "description": "Tommy Williams Homes beckton Model BA10 benchmark file", "downloadURL": "https://data.openei.org/files/4588/twh-b10-benchmark.xml", "format": "xml", "mediaType": "text/xml", "title": "Tommy Williams Homes BA10 Benchmark Model.xml"}], "identifier": "https://data.openei.org/submissions/4588", "issued": "2016-04-27T06:00:00Z", "keyword": ["BuildingAmerica", "Residential Building", "affordable housing", "building america", "central fan integrated supply ventilation systems", "comfort", "community", "cost effectiveness", "duct systems", "hot humid", "hvac", "indoor air quality", "moisture design", "neutral cost analysis", "production scale housing", "residential", "seasonal energy efficiency ratio", "whole-home"], "landingPage": "https://data.openei.org/submissions/4588", "license": "https://creativecommons.org/licenses/by/4.0/", "modified": "2023-11-01T16:43:49Z", "programCode": ["019:000", "019:002"], "projectNumber": "FY13 AOP 1.9.1.19", "projectTitle": "Building America", "publisher": {"@type": "org:Organization", "name": "University of Central Florida - Florida Solar Energy Center"}, "spatial": "{\"type\":\"Polygon\",\"coordinates\":[[[-88.00999375000004,24.026607255553817],[-78.0015265625,24.026607255553817],[-78.0015265625,31.34826530087072],[-88.00999375000004,31.34826530087072],[-88.00999375000004,24.026607255553817]]]}", "title": "Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate"}