{"@type": "dcat:Dataset", "accessLevel": "public", "accrualPeriodicity": "irregular", "bureauCode": ["006:55"], "contactPoint": {"fn": "Dongsoo Jang", "hasEmail": "mailto:dongsoo.jang@nist.gov"}, "description": "This TRNSYS building energy simulation model is developed for a Net-Zero Energy Building (NZEB) located on the National Institute of Standards and Technology (NIST) campus in Gaithersburg, Maryland, USA. The model integrates a two-capacity ground-source heat pump (GSHP), a heat pump water heater (HPWH), an energy recovery ventilator (ERV), a whole-house dehumidifier, and a photovoltaic (PV) array to simulate building performance. Key outputs include energy consumption, thermal loads, occupant comfort, and more.The model has been utilized in the following journal paper:Jang, D.S. and Skye, H.M. (2024), \"Performance of a ground-source integrated heat pump for HVAC and DHW in a residential net-zero energy building,\" Energy Conversion and Management, 321, 119003, https://doi.org/10.1016/j.enconman.2024.119003.", "distribution": [{"downloadURL": "https://data.nist.gov/od/ds/mds2-3577/TRNSYS_NZEB_GSHP.zip", "mediaType": "application/x-zip-compressed", "title": "TRNSYS_NZEB_GSHP"}], "identifier": "ark:/88434/mds2-3577", "issued": "2024-11-21", "keyword": ["Domestic hot water", "Ground-source heat pump", "HVAC", "Net-zero energy building", "TRNSYS simulation"], "landingPage": "https://data.nist.gov/od/id/mds2-3577", "language": ["en"], "license": "https://www.nist.gov/open/license", "modified": "2024-10-10 00:00:00", "programCode": ["006:045"], "publisher": {"@type": "org:Organization", "name": "National Institute of Standards and Technology"}, "references": ["https://doi.org/10.1016/j.enconman.2024.119003"], "theme": ["Buildings and Construction:Air conditioning and heating equipment", "Energy:Alternative energy", "Energy:Energy efficiency"], "title": "TRNSYS Building Energy Simulation Model for a Net-Zero Energy Building with a Ground-Source Heat Pump"}