  "accessLevel": "public",
  "bureauCode": [
    "020:00"
  ],
  "contactPoint": {
    "fn": "Jonathan Krug",
    "hasEmail": "mailto:krug.jonathan@epa.gov"
  },
  "description": "Wind tunnel evaluation of EPA's Hi-Vol TSP sampler for sampling effectiveness with regards to aerodynamic particle diameter (5 to 35 microns), wind speed (2, 8, 24 km/hr), orientation (0, 45, and 90 degrees relative to wind vector), and operational state (ON or OFF). A Coulter Counter analysis of the three Arizona Test Dust mixtures is presented. \n\nThis dataset is associated with the following publication:\nKrug, J., A. Dart, C. Witherspoon, J. Gilberry, Q. Malloy, S. Kaushik, and R. Vanderpool. Review of the of EPA's High-Volume Total Size Selective Performance  (Hi-Vol TSP) Sampler.   AEROSOL SCIENCE AND TECHNOLOGY. Taylor & Francis, Inc., Philadelphia, PA, USA, 0(0): 1-20, (2017).",
  "distribution": [
    {
      "downloadURL": "https://pasteur.epa.gov/uploads/572/HiVolData_ScienceHub.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "title": "HiVolData_ScienceHub.xlsx"
    }
  ],
  "identifier": "A-fxq2-572",
  "keyword": [
    "Hi-Vol TSP",
    "Size selective performance",
    "total suspended particulate",
    "wind tunnel"
  ],
  "license": "https://pasteur.epa.gov/license/sciencehub-license.html",
  "modified": "2017-04-26",
  "programCode": [
    "020:094"
  ],
  "publisher": {
    "name": "U.S. EPA Office of Research and Development (ORD)",
    "subOrganizationOf": {
      "name": "U.S. Environmental Protection Agency",
      "subOrganizationOf": {
        "name": "U.S. Government"
      }
    }
  },
  "references": [
    "https://doi.org/10.1080/02786826.2017.1316358"
  ],
  "rights": null,
  "title": "Wind tunnel evaluation of Hi-Vol TSP effectiveness data"
}