This data set consists of
electric field waveform samples from the Voyager 2 Plasma Wave
Receiver waveform receiver obtained during the Uranus encounter.
The waveforms are collections of 4-bit samples of the electric
field measured by the dipole electric antenna at a rate of 28,800
samples per second. 1600 samples are collected in 55.56 msec
followed by a 4.44-msec gap. Each 60-msec interval constitutes a
line of waveform samples. The data set includes about 271 frames of
waveform samples consisting of up to 800 lines, each. The
telemetry format for the waveform data is identical to that for
images, hence the use of line and frame as constructs in describing
the form of the data. The waveform is sampled through a bandpass
filter with a passband of 40 Hz to 12 kHz. The 4-bit samples
provide sixteen digital values of the electric field with a
linear amplitude scale, but the amplitude scale is arbitrary
because of the automatic gain control used in the waveform
receiver. The instantaneous dynamic range afforded by the 4
bit samples is about 23 db, but the automatic gain control allows
the dominant signal in the passband to be set at the optimum
level to fit within the instantaneous dynamic range. With the gain
control, the overall dynamic range of the waveform receiver
is about 100 db.