Combined Scanning Confocal Ultrasound Diagnostic and Treatment System for Bone Quality Assessment and Fracture Healing

Metadata Updated: May 2, 2019

The objectives of this study are to develop a combined diagnostic and treatment ultrasound technology for early prediction of bone disorder and guided acceleration of fracture healing, using SCAN imaging and low-intensity pulse ultrasound. The technology will target to the critical skeletal sites, where may be significantly affected by disuse osteopenia and potentially at the risk of fracture. The research team has been focused on the technology development of the SCAN system and on determining interrelationship between ultrasound parameters and bone's structural and strength properties in a quantitative manner. The results have demonstrated the feasibility and efficacy of SCAN for assessing bone's quality in animal, human cadaver bone samples, and in vivo human subjects (e.g., bed rest). 13 peer-reviewed journal papers and more than 36 conference short papers were published in this period directly derived from this work.
Musculoskeletal complications induced by age-related diseases like osteoporosis, and in long-term disuse osteopenia such as a lack of microgravity during extended space missions and long-term bed rest, represent a key health problem. Such a skeletal disorder changes both the structural and strength properties of bone, and the latter plays a critic role in ultimately leading to fracture. Early diagnosis of progressive bone loss or poor bone quality would allow prompt treatment and thus will dramatically reduce the risk of bone fracture. While most of the osteoporotic fractures occur in cancellous bone, non-invasive assessment of trabecular strength and stiffness is extremely important in evaluating bone quality. Ultrasound has also been shown therapeutic potentials to accelerate fracture healing. We are able to develop a SCAN system combined with therapeutic ultrasound capable of generating acoustic images at the regions of interest for identifying the strength of trabecular bone, in which the system is capable of generating non-invasive, high-resolution ultrasound (US) attenuation and velocity maps of bone, and thus determining the relationship between ultrasonic specific parameters and bone mineral density (BMD), and bone strength and bone's physical properties (i.e., stiffness and modulus). The ultrasound resolution and sensitivity are significantly improved by its configuration, compared to the existing technology. Developed prototype of SCAN is successfully used in the bedrest subjects and clinical test (Stony Brook University). A fast scan mode (~2.5 min) and a surface topology mapping technology using scanning ultrasound are developed and capable of determining calcaneus bone thickness accurately and hence enhancing the accuracy of UV measurement. Ultrasound treatment for progressive bone loss is also initiated in this year's research.

Access & Use Information

Public: This dataset is intended for public access and use. License: U.S. Government Work

Downloads & Resources

Dates

Metadata Created Date August 1, 2018
Metadata Updated Date May 2, 2019

Metadata Source

Harvested from NASA Data.json

Additional Metadata

Resource Type Dataset
Metadata Created Date August 1, 2018
Metadata Updated Date May 2, 2019
Publisher Space Technology Mission Directorate
Unique Identifier TECHPORT_23200
Maintainer
TECHPORT SUPPORT
Maintainer Email
Public Access Level public
Bureau Code 026:00
Metadata Context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
Metadata Catalog ID https://data.nasa.gov/data.json
Schema Version https://project-open-data.cio.gov/v1.1/schema
Catalog Describedby https://project-open-data.cio.gov/v1.1/schema/catalog.json
Datagov Dedupe Retained 20190501230127
Harvest Object Id 6b6be579-3fa9-41e9-9a83-77b45ddf2146
Harvest Source Id 39e4ad2a-47ca-4507-8258-852babd0fd99
Harvest Source Title NASA Data.json
Data First Published 2013-08-01
Homepage URL https://techport.nasa.gov/view/23200
License http://www.usa.gov/publicdomain/label/1.0/
Data Last Modified 2018-07-19
Program Code 026:027
Source Datajson Identifier True
Source Hash e0da3236132439711806a4f98b807b4d79706a57
Source Schema Version 1.1

Didn't find what you're looking for? Suggest a dataset here.