The Psychrometric Test Chamber’s primary purpose is to evaluate the performance of split type central air conditioners and heat pumps in the cooling capacity range of 12,000 to 70,000 Btu/h (1 to 5 ½ rated tons). It consists of side-by-side indoor and outdoor chambers with temperature, humidity and air flow controlled independently. The Test Chamber is designed to maintain a single set of operating conditions and is able to maintain conditions within the following dry bulb and web bulb temperature ranges:  indoor = 45°F to 100°F DB; 43°F to 85°F WB; outdoor = 10°F to 120°F DB; 35°F to 90.5°F WB. The Balanced Ambient Calorimeter Test Chamber's primary purpose is to evaluate the performance of room air conditioners (split, window, or wall-type), packaged terminal air conditioners, and packaged terminal heat pumps in the cooling capacity range of 6,000 to 42,000 Btu/h (½ to 3 ½ rated tons). It consists of side-by-side indoor and outdoor chambers with temperature, humidity and air flow controlled independently. Both the indoor room and the outdoor room are surrounded by an annular space which independently maintains the same temperature and humidity as the rooms it surrounds. The Test Chamber is designed to maintain a single set of operating conditions and is able to maintain conditions within the following dry bulb and web bulb temperature ranges: indoor = 45°F to 100°F DB; 43°F to 79°F WB; outdoor = 10°F to 120°F DB; 40°F to 81°F WB.

Access & Use Information

Public: This dataset is intended for public access and use. License: No license information was provided. If this work was prepared by an officer or employee of the United States government as part of that person's official duties it is considered a U.S. Government Work.

Downloads & Resources

Dates

Metadata Created Date March 8, 2017
Metadata Updated Date March 8, 2017

Metadata Source

Harvested from Federal Laboratory Consortium Data.json

Additional Metadata

Resource Type Dataset
Metadata Created Date March 8, 2017
Metadata Updated Date March 8, 2017
Publisher Federal Laboratory Consortium
Unique Identifier 3971D2BA-4E34-4B73-A8B8-B6A4AD84CCA4
Maintainer
Maintainer Email
None
Public Access Level public
Address1 1 Cyclotron Road
Address2
Address3
Metadata Context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
Schema Version https://project-open-data.cio.gov/v1.1/schema
Catalog Describedby https://project-open-data.cio.gov/v1.1/schema/catalog.json
Expertise
Fax
Flcbusinessurl https://flcbusiness.federallabs.org/#/laboratory/4721
Harvest Object Id a03f01f8-730b-4a72-a13e-24d7d050ab14
Harvest Source Id 5859cfed-553c-48de-a478-b67b5225f6fc
Harvest Source Title Federal Laboratory Consortium Data.json
Mission
Owneroperatorcode
Phone 510-486-4540
Postalcode 94720
Repphone
Sizesqft
Source Datajson Identifier True
Source Hash acc39bfab903e9a53d500b375ab0a4e486bff162
Source Schema Version 1.1
Statecode CA
T2Website

Didn't find what you're looking for? Suggest a dataset here.