Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 2
Resources
1 resource available
-
DOI Access to Dataset from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 2
FILE
Find Related Datasets
Search by Tags
Click any tag below to search for similar datasets
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| accrualPeriodicity | irregular |
| bureauCode |
[ "006:55" ] |
| contactPoint |
{ "fn": "Matthew Hoehler", "hasEmail": "mailto:matthew.hoehler@nist.gov" } |
| description | Twenty-two 2.7 m by 3.7 m shear wall specimens consisting of 150 mm wide CFS framing were tested. All walls were designed to achieve a 1-hour fire-resistance rating per American Society for Testing and Materials (ASTM) standard E119. Heating was applied to the side of the wall opposite to the side where the shear-resisting elements are located; it is assumed that the shear-resisting elements line an egress corridor and the fire occurs in a room adjacent to the corridor. The walls are designed using Allowable Stress Design nominally following American Iron and Steel Institute (AISI) standards S400-15/S1-16 and AISI S100-16. |
| distribution |
[ { "title": "DOI Access to Dataset from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 2", "accessURL": "https://doi.org/10.18434/M32041" } ] |
| identifier | 848DBEBF057D6362E053245706813C122041 |
| keyword |
[ "NFRL", "cold-formed steel", "earthquake", "fire", "oriented strand board", "shear wall", "steel sheathed", "strap braced" ] |
| landingPage | https://www.nist.gov/el/fire-research-division-73300/national-fire-research-laboratory-73306/influence-fire-lateral-0 |
| language |
[ "en" ] |
| license | https://www.nist.gov/open/license |
| modified | 2019-03-20 00:00:00 |
| programCode |
[ "006:045" ] |
| publisher |
{ "name": "National Institute of Standards and Technology", "@type": "org:Organization" } |
| references |
[ "https://doi.org/10.6028/NIST.TN.2038" ] |
| theme |
[ "Fire:Structural fire resistance" ] |
| title | Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 2 |